 Your new post is loading...
 Your new post is loading...
|
Scooped by
AEOPTOMETRISTAS
May 21, 2014 7:02 AM
|
The Ocular Surface, Volume 12, Issue 2, Pages S1-S31, April 2014, Authors:Anthony J. Bron, FRCOphth, F.MedSci; Alan Tomlinson, PhD, DSc, FCOptom; Gary N. Foulks, MD, FACS; Jay S. Pepose, MD, PhD; Christophe Baudouin, MD, PhD; Gerd Geerling, MD, FEBO; Kelly K. Nichols, OD, MPH, PhD; Michael A. Lemp, MD Abstract Publication of the DEWS report in 2007 established the state of the science of dry eye disease (DED). Since that time, new evidence suggests that a rethinking of traditional concepts of dry eye disease is in order. Specifically, new evidence on the epidemiology of the disease, as well as strategies for diagnosis, have changed the understanding of DED, which is a heterogeneous disease associated with considerable variability in presentation. These advances, along with implications for clinical care, are summarized herein.
|
Scooped by
AEOPTOMETRISTAS
May 14, 2014 4:36 AM
|
Contact Lens & Anterior Eye, Volume 37, Issue 2, Pages 116-119, April 2014, Authors:Ka Yin Chan; Sin Wan Cheung; Pauline Cho Abstract Purpose To compare the axial length elongation and change in refractive errors in a pair of identical twins wearing orthokeratology (ortho-k) and single vision lenses (SVLs), respectively. Case report Identical Twin A and B, who were 8 years of age, with the same amount of near activities, were assigned to wear ortho-k and SVLs randomly and they were monitored for two years for myopic progression. Twin A and B were assigned to wear ortho-k and SVLs, respectively. Myopic progression was evaluated by the change in axial length and in refractive errors. A faster axial length elongation was observed in each eye of Twin B during the two-year study period. The overall change in axial length was 0.52mm (OD) and 0.70 (OS) in Twin A and 0.77mm (OD)
|
Scooped by
AEOPTOMETRISTAS
May 7, 2014 5:00 AM
|
Volume 157, Issue 5, May 2014, Pages 1077–1089.e1 Pablo Pérez-Merino , Judith Birkenfeld, Carlos Dorronsoro, Sergio Ortiz, Sonia Durán, Ignacio Jiménez-Alfaro, Susana Marcos
Purpose To evaluate the objective accommodative response, change of aberrations, and depth of focus in eyes implanted with the Crystalens accommodative intraocular lens (IOL) at different accommodative demands.
Design Prospective, observational study. Methods Eleven cataract patients (22 eyes) who underwent implantation of a Crystalens accommodative IOL, and control groups of 9 normal subjects (17 eyes) and 17 pseudophakic patients (17 eyes) implanted with monofocal IOLs were evaluated. A custom-developed laser ray tracing aberrometer was used to measure the optical aberrations. The monochromatic wave aberrations were described using a sixth-order Zernike polynomial expansion. Measurements were obtained under dilated and natural viewing conditions (for accommodative efforts ranging from 0 to 2.5 diopters [D]).
|
Scooped by
AEOPTOMETRISTAS
May 7, 2014 4:35 AM
|
Volume 39, March 2014, Pages 58–76 Abstract The retinal circadian system represents a unique structure. It contains a complete circadian system and thus the retina represents an ideal model to study fundamental questions of how neural circadian systems are organized and what signaling pathways are used to maintain synchrony of the different structures in the system. In addition, several studies have shown that multiple sites within the retina are capable of generating circadian oscillations. The strength of circadian clock gene expression and the emphasis of rhythmic expression are divergent across vertebrate retinas, with photoreceptors as the primary locus of rhythm generation in amphibians, while in mammals clock activity is most robust in the inner nuclear layer. Melatonin and dopamine serve as signaling molecules to entrain circadian rhythms in the retina and also in other ocular structures. Recent studies have also suggested GABA as an important component of the system that regulates retinal circadian rhythms.
|
Scooped by
AEOPTOMETRISTAS
April 30, 2014 12:36 PM
|
Oftálmica y Óptica Fisiológica Número especial: La visión binocular: del laboratorio a la clínica Volumen 34 , Número 2 , páginas 186-198 , marzo 2014 Ifan Betina Ip 1,2, * , Loredana Minini 3 James Dow 1 , Andrew J. Parker 1,2 y Acebo Puente 2
Abstracto PropósitoPercibiendo la profundidad binocular se basa en la capacidad de nuestro sistema visual para que coincida con precisión las características correspondientes en los ojos izquierdo y derecho. Sin embargo, cómo el cerebro humano extrae correlación disparidad interocular es poco conocido. MétodosSe utilizó imágenes de resonancia magnética funcional (fMRI) para caracterizar las regiones cerebrales implicadas en el procesamiento de correlación disparidad interocular. Mediante la variación de la cantidad de correlación interocular de una disparidad-definido al azar-
|
Scooped by
AEOPTOMETRISTAS
April 24, 2014 11:33 PM
|
Juan Tabernero, Pablo Artal mail Published: April 22, 2014 DOI: 10.1371/journal.pone.0095764
Abstract: The eye changes gaze continuously from one visual stimulus to another. Using a high speed camera to record eye and lens movements we demonstrate how the crystalline lens sustains an inertial oscillatory decay movement immediately after every change of gaze. This behavior fit precisely with the movement of a classical damped harmonic oscillator. The time course of the oscillations range from 50 to 60 msec with an oscillation frequency of around 20 Hz. That has dramatic implications on the image quality at the retina on the very short times (~50 msec) that follow the movement. However, it is well known that our vision is nearly suppressed on those periods (post-saccadic suppression). Both phenomenon follow similar time courses and therefore might be synchronized to avoid the visual impairment.
|
Scooped by
AEOPTOMETRISTAS
April 23, 2014 4:32 AM
|
.. Vol. 07 Núm. 01 Enero 2014 - Marzo 2014 Soyeon Kim , Samantha Chen , Rosemary Tannock
Propósito La visión del color y la función visual de auto-reporte en la vida cotidiana de los jóvenes adultos con Trastorno de Atención (ADHD) fueron investigados. Método Los participantes fueron 30 adultos jóvenes con TDAH y 30 controles emparejados por edad y sexo. Ellos fueron probados individualmente y completaron el cuestionario sobre actividades Visual (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) y una prueba rápida de Cognitive Velocidad (AQT).
|
Scooped by
AEOPTOMETRISTAS
April 10, 2014 10:47 AM
|
Influencia de los factors prenatales en el Desarrollo del nervio óptico y de la retina Irene Altermi, Victoria Pueyo, Noemí Elía, Daniel de Oros
|
Scooped by
AEOPTOMETRISTAS
April 9, 2014 6:52 AM
|
Häntzschel J. · Terai N. · Furashova O. · Pillunat K. · Pillunat LE
Departamento de Oftalmología, Hospital Carl Gustav Carus Universidad, Dresden, Alemania Ophthalmologica 2014; 231:160-165 (DOI: 10.1159/000355326) Abstracto Objetivo: El objetivo de este estudio fue investigar las diferencias en la capa de fibras nerviosas y la cabeza estructural inducida por glaucoma de nervio óptico (CNO) en pacientes con daño normal (GTN) y alta tensión (HTG) glaucoma. Métodos: En esta retrospectiva estudio comparativo por parejas, 22 NTG y 22 ojos HTG fueron agrupados de acuerdo con el mismo daño glaucomatoso basado en el volumen de la llanta, el área de borde y el tamaño del disco, tal como se mide por la tomografía de retina Heidelberg (HRT III). Campo visual (VF) se evaluaron mediante perimetría Humphrey, y grosor de la capa de fibras nerviosas se determinó tanto mediante el escaneo de polarimetría láser (GDxVCC) y dominio espectral tomografía de coherencia óptica (SD-OCT).
|
Scooped by
AEOPTOMETRISTAS
April 9, 2014 6:34 AM
|
Contact Lens & Anterior Eye, Volume 37, Issue 2, Pages 92-98, April 2014, Authors:Richard M. Pearson Abstract Purpose To provide an overview of the use of contact lenses by RAF aircrew in World War II by identifying some of the fitters and wearers and appraising the clinical results that they achieved. Methods A wide-ranging literature search was undertaken that encompassed peer-reviewed journals, non-refereed publications, books, official publications, newspapers and archived documents.
|
Scooped by
AEOPTOMETRISTAS
April 7, 2014 12:58 AM
|
Variación del espesor retiniano en el área macular respecto de la longitud axial en ojos con miopía patológica Autores: Ahmad Zaben Omran, José Alberto De Lazro Yagüe i Miquel Ralló
|
Scooped by
AEOPTOMETRISTAS
March 22, 2014 6:17 AM
|
Safety and compliance of prescription spectacles ordered by the public via the Internet Karl Citek, un Daniel L. Torgersen, Jeffrey D. Endres, Robert R. Rosenberg, Optometría, 2011 septiembre, 82 (9): 549-555
|
Scooped by
AEOPTOMETRISTAS
March 20, 2014 6:43 AM
|
. Oftalmología 2014 Feb; 121 (2) :525-34. doi: 10.1016/j.ophtha.2013.09.038. Christen WG , Glynn RJ , Manson JE , MacFadyen J , bubes V , Schvartz M , Buring JE , Sesso HD , Gaziano JM . Abstracto PROPÓSITO:Para probar si los suplementos multivitamínicos a largo plazo afecta la incidencia de cataratas o la degeneración macular relacionada con la edad (AMD) en una gran cohorte de hombres. DISEÑO:, Aleatorizado, doble ciego y controlado con placebo. PARTICIPANTES:Un total de 14.641 médicos varones estadounidenses de edad ≥ 50 años. INTERVENCIÓN:Multivitamínico o un placebo diario.
|
|
Scooped by
AEOPTOMETRISTAS
May 14, 2014 4:39 AM
|
Ojos y Lentes de Contacto: Ciencia y práctica clínica: Tagliaferri, Angela MS; Amor, Thomas E. Ph.D.; Szczotka-Flynn, Loretta BOD, MS, Ph.D. Antecedentes: Contacto inducida por lentes papilar conjuntivitis (CPLC) continúa siendo una de las principales causas de deserción escolar durante el uso prolongado de lentes de contacto. Este estudio retrospectivo explora los factores de riesgo para el desarrollo de CPLC durante el uso prolongado de lentes de hidrogel de silicona. Métodos: Los datos de 205 subj ...
|
Scooped by
AEOPTOMETRISTAS
May 14, 2014 4:33 AM
|
La superficie ocular, Volumen 12, Número 2, páginas 100-111, abril de 2014, Autores: Michael J. Doughty, PhD Resumen Propósito Para revisar los resultados de los estudios en los que se habían hecho el tiempo de ruptura lagrimal con fluoresceína (fTBUT) mediciones antes y después del tratamiento con lágrimas artificiales. Métodos Se identificaron artículos revisados por pares que informa valores promedio para fTBUT antes y después de aproximadamente 1 mes de tratamiento del ojo seco de lágrimas artificiales de base acuosa. 48 conjuntos de datos se utilizaron para el cálculo de la red (porcentaje) cambio en fTBUT, con 21 incluyendo información de la variabilidad (como SD informado de media V
|
Scooped by
AEOPTOMETRISTAS
May 7, 2014 4:55 AM
|
JAMA Ophthalmol. Published online April 03, 2014. doi:10.1001/jamaophthalmol
Evelyn C. O’Neill, MB, BCh, BAO, MD, MRCOphth; Lulu U. Gurria, MD; Surinder S. Pandav, MBBS, MS; Yu Xiang G. Kong, MBBS, PhD; Jessica F. Brennan, BOrth&OphthalSc; Jing Xie, MD, PhD; Michael A. Coote, MBBS, FRANZCO; Jonathan G. Crowston, PhD, FRANZCO1 Abstract Importance Glaucoma is a significant health problem for which diagnosis remains suboptimal. Optic disc evaluation, which is fundamental to the diagnosis, is a difficult skill to acquire. Objectives To determine the optic disc characteristics that most influence decision making in the assessment of glaucoma likelihood and to ascertain the optic disc features associated with overestimation and underestimation of glaucoma likelihood.
|
Scooped by
AEOPTOMETRISTAS
April 30, 2014 12:42 PM
|
Article Outline
Rose bengal stain (4,5,6,7-tetrachloro-2',4',5',7'-tetraiodofluorescein) is fluorescein with the addition of halogens to produce molecules with a different color (Figure 1). In the late XIX century, Ghnem added halogens to the recently patented fluorescein to produce diverse chromatic hues for use in dying wool. In 1882 he patented a red dye (German patent No. 32584) named “rose bengal.” It is unknown why this name was chosen, but it could be because its color was similar to the dot (tika) painted on the center of the forehead by women of the Bengali region
|
Scooped by
AEOPTOMETRISTAS
April 30, 2014 12:28 PM
|
Viso, Eloy MD, PhD * ; Rodríguez-Ares, María T. MD, PhD †, ‡ ; Bóveda, Francisco J. MD * ; Touriño, Rosario MD, PhD † ; Gude, Francisco MD, PhD § Córnea: Objetivo: El objetivo de este estudio fue describir las características epidemiológicas de la retracción conjuntival (CS) y la asociación entre este trastorno y la enfermedad del ojo seco (DED) en una población adulta en general en el noroeste de España. Métodos: Un total de 1.155 sujetos 40 años o más viejos eran seleccione ...
|
Scooped by
AEOPTOMETRISTAS
April 23, 2014 4:37 AM
|
Naghizadeh, Farzaneh MD * ; Garas, Anita MD, PhD * ; Vargha, Péter MSc † ; Holló, Gábor MD, PhD, DSc Journal of Glaucoma: Finalidad:. Para investigar la capacidad de los diferentes parámetros de la Fourier-domain tomógrafo de coherencia óptica RTVue-100 (RTVue-OCT) para detectar precozmente la progresión glaucomatosa Métodos: Un ojo de 17 sanos y 51 pacientes con glaucoma perimétricos fue fotografiada de forma prospectiva a los 6 meses intervalos de 1,5 a ...
|
Scooped by
AEOPTOMETRISTAS
April 23, 2014 4:29 AM
|
The Ocular Surface Volume 12, Issue 1 , Pages 10-13, January 2014
Ivan Cher, FRCS, FRANZCO
This editorial examines the elusive history of the origin and development of ocular surface (OS) concepts through literature sources, predominantly primary. The relevance of two papers long regarded as having introduced the OS concept in 1977–78 is explored. A later 1979 publication from a primary source is more apposite.
|
Scooped by
AEOPTOMETRISTAS
April 10, 2014 10:38 AM
|
EFECTOS ADVERSOS EN CIRUGÍA CON LÁSER Refractiva corneales: REVISIÓN DE ALCANCE Ana Tobarra López, Mercedes López Hernández, Diana Gil-González, Carlos Álvarez-Dardet
|
Scooped by
AEOPTOMETRISTAS
April 9, 2014 6:37 AM
|
Eye & Contact Lens: Science & Clinical Practice:
Williamson, Jennifer F. M.D.; Huynh, Kyle B.S.; Weaver, Mark A. Ph.D.; Davis, Richard M. M.D Objective:To assess the perceptions of eye care providers regarding the clinical management of dry eye. Methods:Invitations to complete a 17-question online survey were mailed to 400 members of the North Carolina Ophthalmology and Optometry Associations including community optometrists, comprehe...
|
Scooped by
AEOPTOMETRISTAS
April 7, 2014 1:05 AM
|
Correlación de la Sensibilidad retiniana en la microperimetría Con El Espesor macular y coroideo en la miopía patológica Ahmad Zaben & Miguel Ángel Zapata
|
Scooped by
AEOPTOMETRISTAS
March 24, 2014 2:15 AM
|
Grupo de Estudios AEOPTOMETRISTAS (GEA), una gran labor profesional por la investigación
|
Scooped by
AEOPTOMETRISTAS
March 20, 2014 6:54 AM
|
JAMA Ophthalmol . Publicado en Internet el 27 de febrero de 201 Matthew P. Simunovic, MB, Bchir, PhD Abstracto ¿En qué medida la obra de un artista representa su mundo perceptual, y en qué medida puede atributos de su trabajo se atribuye a defectos sensoriales? Estos temas se encuentran en el centro de una conjetura más de un siglo de antigüedad, que ha sido denominado la falacia de El Greco . La falacia de El Greco postula que el alargamiento evidente en el arte de El Greco refleja un alargamiento de percepción subyacente de los objetos producidos por el astigmatismo. La refutación "lógica" de esta teoría sostiene que cualquier alargamiento perceptual que El Greco puede haber sufrido como consecuencia de astigmatismo habría causado no sólo a sus súbditos a ser alargadas, sino también su lienzo. Por lo tanto, debería haber sido necesario para él para alargar sus cuadros para que coincida con su percepción. Esta objeción es importante porque nos advierte en contra de sacar la conclusión errónea de que la obra de un artista representa un facsímil de su percepción. Sin embargo, un análisis de los efectos de astigmatismo en la imagen retiniana sugiere que esta refutación "lógica" de la falacia de El Greco promulga otra falacia: la de astigmatismo como fuente de un erro perceptual constante
|
Repensando el síndrome de ojo seco una mirada hacia Implicaciones clínicas